Description
The Bilco RL2-S is the Bil-Guard 2.0 roof hatch rail system for the standard 36 x 30 inch hatch, including the Bilco S-20. It is a permanent guardrail with a self-closing gate that bolts to the hatch capflashing, so it goes on without penetrating the roof membrane and satisfies OSHA 29 CFR 1910.29 with a factor of safety of two. Logistics Lighting quotes the RL2-S with the hatch and ladder safety post that complete the access point and ships direct from Bilco.
Key features of the Bil-Guard 2.0 RL2-S
- Mounts to the capflashing. Extruded aluminum brackets clamp to the hatch flashing, so nothing is drilled into the roof and the roofing warranty is untouched.
- Self-closing gate. Stainless steel self-closing hinges and a positive latch keep a continuous barrier around the opening while someone is on the ladder.
- High-visibility finish. Safety yellow powder coat as standard; other colors as a special order.
- Corrosion resistant. 6061-T6 aluminum rails and posts, cast aluminum post guides and latch, Type 316 stainless fasteners, five-year warranty.
- Field assembled. Ships as a kit with the mounting brackets and instructions; assembly is by the installer per Bilco's manual.
Specifications
- Fits: 36 x 30 in Bilco roof hatches (S-20, S-50, S-90); gate on the 30 inch side
- Posts and rails: 1-1/4 in (32 mm) 6061-T6 Schedule 40 aluminum pipe
- Mounting brackets: 3/8 in (9 mm) thick extruded aluminum
- Post guides and latch: cast aluminum with compression fittings
- Hinges and fasteners: Type 316 stainless steel
- Compliance: OSHA 29 CFR 1910.29, strength requirements at a safety factor of two
- Other Bil-Guard 2.0 models: RL2-NB, RL2-L, RL2-E, RL2-F, RL2-SS and RL2-D for other hatch and fire vent sizes, quoted on request
Why a hatch needs a rail
OSHA 1910.28 classifies an open roof hatch as a hole, and a worker stepping off the ladder onto the roof has an unprotected opening at their feet. A fixed rail with a self-closing gate is the simplest permanent fix because it needs no personal fall-arrest gear and no training beyond closing the gate. Pair it with the LU-1 Ladder Up post so the climber also has a handhold above the roof line. Kattsafe's KG is a clamp-on alternative for hatches from other manufacturers.
Frequently asked questions
Does the RL2-S fit a thermally broken hatch? No. Use the RL2-STB for the S-50TB and other thermally broken Bilco hatches.
Can it be retrofitted to an existing hatch? Yes, provided the hatch is a Bilco 36 x 30 with an intact capflashing. Send us a photo of the flashing and we will confirm.
Is the gate included? Yes. The self-closing gate, hinges and latch are part of the kit.
How to get a quote
Send the ladder and hatch worksheet or call 307-633-9696 with the hatch model it will mount to and the quantity. We confirm fit and the current Bilco lead time on the quote. The cut sheet, installation manual and three-part specification are in the Documents tab.
Related reading: OSHA fall protection for skylights, in our daylighting library.
- Videos
- Warranty
-
Documents
The Bilco RL2-S is the Bil-Guard 2.0 roof hatch rail system for the standard 36 x 30 inch hatch, including the Bilco S-20. It is a permanent guardrail with a self-closing gate that bolts to the hatch capflashing, so it goes on without penetrating the roof membrane and satisfies OSHA 29 CFR 1910.29 with a factor of safety of two. Logistics Lighting quotes the RL2-S with the hatch and ladder safety post that complete the access point and ships direct from Bilco.
Key features of the Bil-Guard 2.0 RL2-S
- Mounts to the capflashing. Extruded aluminum brackets clamp to the hatch flashing, so nothing is drilled into the roof and the roofing warranty is untouched.
- Self-closing gate. Stainless steel self-closing hinges and a positive latch keep a continuous barrier around the opening while someone is on the ladder.
- High-visibility finish. Safety yellow powder coat as standard; other colors as a special order.
- Corrosion resistant. 6061-T6 aluminum rails and posts, cast aluminum post guides and latch, Type 316 stainless fasteners, five-year warranty.
- Field assembled. Ships as a kit with the mounting brackets and instructions; assembly is by the installer per Bilco's manual.
Specifications
- Fits: 36 x 30 in Bilco roof hatches (S-20, S-50, S-90); gate on the 30 inch side
- Posts and rails: 1-1/4 in (32 mm) 6061-T6 Schedule 40 aluminum pipe
- Mounting brackets: 3/8 in (9 mm) thick extruded aluminum
- Post guides and latch: cast aluminum with compression fittings
- Hinges and fasteners: Type 316 stainless steel
- Compliance: OSHA 29 CFR 1910.29, strength requirements at a safety factor of two
- Other Bil-Guard 2.0 models: RL2-NB, RL2-L, RL2-E, RL2-F, RL2-SS and RL2-D for other hatch and fire vent sizes, quoted on request
Why a hatch needs a rail
OSHA 1910.28 classifies an open roof hatch as a hole, and a worker stepping off the ladder onto the roof has an unprotected opening at their feet. A fixed rail with a self-closing gate is the simplest permanent fix because it needs no personal fall-arrest gear and no training beyond closing the gate. Pair it with the LU-1 Ladder Up post so the climber also has a handhold above the roof line. Kattsafe's KG is a clamp-on alternative for hatches from other manufacturers.
Frequently asked questions
Does the RL2-S fit a thermally broken hatch? No. Use the RL2-STB for the S-50TB and other thermally broken Bilco hatches.
Can it be retrofitted to an existing hatch? Yes, provided the hatch is a Bilco 36 x 30 with an intact capflashing. Send us a photo of the flashing and we will confirm.
Is the gate included? Yes. The self-closing gate, hinges and latch are part of the kit.
How to get a quote
Send the ladder and hatch worksheet or call 307-633-9696 with the hatch model it will mount to and the quantity. We confirm fit and the current Bilco lead time on the quote. The cut sheet, installation manual and three-part specification are in the Documents tab.